J Cardiovasc Surg (Torino) ; 58(3): 409-415, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25731858

RESUMO

BACKGROUND: The aim of this study was to evaluate the short and mid-term safety and efficacy of the EPIC™ nitinol vascular stent system for the treatment of lesions located in the superficial femoral artery (SFA). METHODS: From October 2010 to June 2012, 83 subjects were enrolled in a prospective, multicenter, non-randomized study designed to demonstrate that the EPIC nitinol vascular stent system for SFA lesions is non-inferior to the published patency rates found in literature. Inclusion criteria were stenosis or occlusion of the SFA or SFA and proximal popliteal artery, with total length from 4 to 11 cm and amenable for treatment with a single stent, in patients with a score from 2 to 5 on Rutherford classification. The primary endpoint was primary patency rate at 12 months as determined by Duplex ultrasound. The secondary endpoints evaluated were: initial arteriographic success, primary patency rate at 6 months, major adverse event rate at one year and technical success. Follow-up with a complete clinical and physical exam, including ABI and Duplex ultrasound was performed at 6 and 12 months. RESULTS: Most patients (56.6%) were men and the mean age was 68.59 (33.1-99.15) years. 25.3% of the total population had intermittent claudication and 73.5% presented with critical limb ischemia. Most lesions were total occlusions (75.9%) and the mean lesion length was 71.16 mm. Contralateral femoral access was performed in 26.5%cases, and ipsilateral femoral approach was used for the remaining 73.5% patients. Technical and arteriographic success was obtained in all 83 (100.00%) patients. Duplex controlled primary patency rate at 6 and 12 months was 95.8% and 76.1%, respectively. The freedom from target lesion revascularization rate was 98.7% and 92.6% at 6 and 12 months, respectively. No stent fractures were observed in this study. Major adverse event rate at 1 year (clinically driven TLR, major amputation, and all-cause mortality) was 15.7%: two target lesion revascularizations (2.4%), one major amputation (1.2%) and ten deaths not related to the procedure (12%). CONCLUSIONS: In conclusion, this study demonstrates the safety and efficacy of the EPIC™ Nitinol Vascular Stent System for the treatment of SFA lesions.


Assuntos
Ligas , Procedimentos Endovasculares/instrumentação , Artéria Femoral , Doença Arterial Periférica/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Índice Tornozelo-Braço , Brasil , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
2.
J Cardiovasc Surg (Torino) ; 58(3): 409-415, 2017. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063653

RESUMO

BACKGROUND: The aim of this study was to evaluate the short and mid-term safety and efficacy of the EPIC™ nitinol vascular stent system for the treatment of lesions located in the superficial femoral artery (SFA).METHODS: From October 2010 to June 2012, 83 subjects were enrolled in a prospective, multicenter, non-randomized study designed to demonstrate that the EPIC nitinol vascular stent system for SFA lesions is non-inferior to the published patency rates found in literature. Inclusion criteria were stenosis or occlusion of the SFA or SFA and proximal popliteal artery, with total length from 4 to 11 cm and amenable for treatment with a single stent, in patients with a score from 2 to 5 on Rutherford classification. The primary endpoint was primary patency rate at 12 months as determined by Duplex ultrasound. The secondary endpoints evaluated were: initial arteriographic success, primary patency rate at 6 months, major adverse event rate at one year and technical success. Follow-up with a complete clinical and physical exam, including ABI and Duplex ultrasound was performed at 6 and 12 months.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Angiografia , Grau de Desobstrução Vascular , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...